Fuse Cut-out Bushing Insulator
Video
Definisi Produk
Bushing minangka insulator listrik berongga sing ngidini konduktor listrik bisa ngliwati penghalang konduktor kanthi aman kayata kasus trafo utawa pemutus sirkuit tanpa kontak listrik. Produsen kita bisa ngasilake bushing porselen miturut standar DIN lan ANSI. Standar.
DIN standar trafo bushing ana kurang volatge bagean accessoires lan dhuwur voltase part kanggo compose.Low bagean voltase kita biasane dijenengi DT1 / 250A, DT1 / 630A, DT1 / 1000A.
Bagean tegangan dhuwur biasane diarani 10NF250A, 10NF630A, 20NF250A, 30NF250A.
Bushing trafo standar ANSI uga ana macem-macem jinis, kayata ANSI Standard 1.2kV threaded secondary transformer bushing, ANSI standar 15kV threaded primer trafo bushing.
Fitting daya minangka aksesoris logam sing nyambungake lan nggabungake macem-macem piranti ing sistem tenaga lan nduweni peran kanggo ngirim beban mekanik, beban listrik lan sawetara perlindungan.
Clamp suspensi utamane digunakake kanggo ndandani konduktor menyang senar insulator utawa nyumerepi konduktor lampu ing menara straightline.Moveover, uga bisa digunakake kanggo menara transposisi kanggo ndhukung konduktor transposisi lan menara tension utawa kutub sudut kanggo ndandani kabel jumper.
Fuse Porcelain bushing (IEC ANSIAS) | ||||||||||||||||
Gambar no | 72101 | 72102 | 72103 | 72201 | 72202 | 72203 | 72204 | 72205 | 72206 | 72207 | 72208 | 72209 | 72210 | 722301 | 722302 | |
Cat.No. | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 3 | 4 | 5 | 4 | 4 | 4 | 6 | 6 | |
Dimensi Utama | ||||||||||||||||
Dhiameter (D) | mm | 287 | 287 | 287 | 376 | 375 | 376 | 376 | 376 | 375 | 467 | 376 | 365 | 375 | 467 | 467 |
Dhiameter (d) | mm | 87 | 90 | 105 | 90 | 96 | 87 | 102 | 131 | 129 | 96 | 127 | 150 | 155 | 130 | 121 |
dhuwur | mm | 32 | 32 | 32 | 32 | 35 | 32 | 35 | 35 | 32 | 32 | 32 | 35 | 35 | 35 | 32 |
Jarak creep | mm | 220 | 240 | 255 | 300 | 340 | 280 | 360 | 470 | 460 | 432 | 450 | 500 | 550 | 660 | 660 |
Nilai Listrik | ||||||||||||||||
Kelas voltase | kv | 15 | 15 | 15 | 25 | 25 | 25 | 25 | 24/27 | 24/27 | 25/27 | 24/27 | 24/27 | 25/27 | 33/36 | 33/36 |
Kekuatan kantilever | kv | 18 | 18 | 20 | 10/12.5 | 10 | 10 | 10 | 10 | 10 | 6.8/10 | 10 | 10 | 10 | 6.8/10 | 6.8/10 |
Data Packing lan Pengiriman | ||||||||||||||||
Bobot net, kira-kira | kg | 2.6 | 2.8 | 3.2 | 3.5 | 3.7 | 3.4 | 3.9 | 5.8 | 6.0 | 5.2 | 5.8 | 6.5 | 6.9 | 7.5 | 7.5 |
Nomer kandang | 8 | 8 | 8 | 12 | 12 | 12 | 12 | 12 | 10 | 17 | 10 | 10 | 10 | 16 | 16 |
Produk Gunakake
Bushing kudu dirancang kanggo nahan kekuatan medan listrik sing diasilake ing insulasi, nalika ana materi sing ana bumi.Nalika kekuwatan medan listrik mundhak, jalur bocor bisa berkembang ing insulasi.Yen energi saka jalur bocor ngatasi kekuatan dielektrik saka jampel, bisa puncture jampel lan ngidini energi listrik kanggo nindakake kanggo materi earthed paling cedhak nyebabake kobong lan arcing.
Bushing terisolasi bisa dipasang ing njero ruangan utawa ruangan, lan pilihan insulasi bakal ditemtokake dening lokasi instalasi lan tugas layanan listrik ing bushing.